Aligned LBB-01 Data Center

1498 County Road 315, Abernathy, TX 79311

PlannedAligned Data CentersAbernathyAligned Data Centers site

  • Wholesale
  • Verified November 2026
  • 5 compliance reports

About Aligned LBB-01

Aligned LBB-01 is a wholesale data center operated by Aligned Data Centers at 1498 County Road 315 in Abernathy, TX. It's one of 1 facilities we track in the Abernathy market, a tier 3 market.

UPS redundancy is 2 MW UPS line-ups; N+1 block redundant and generators are 3 MW backup generators. Cooling is Minimum N+1; closed-loop chilled water.

Security includes 5-layer security, 24x7x365 onsite security staff and fixed and PTZ cameras.

Status not stated by Aligned.

  • Industry leaders, not a call centerOur team brings 20 to 30 years from major data center platforms, the channel and data center brokerage.
  • Pricing in days, not weeksOne request reaches the providers that fit. No chasing reps one by one.
  • We negotiate, you signWe know what buyers in this market pay and use it to get you better terms.

Aligned LBB-01 key details

Building size
Not published
Colocation space
Not published
Total power
Not published
Critical IT power
Not published
Availability
Not published
Market
Abernathy
Type
Wholesale
Specs checked
November 2026

Buyer note: Aligned Data Centers does not publish critical IT power, available capacity, power density per rack and carrier count for Aligned LBB-01. That is common, and it is exactly what to ask for in writing with your quote. We confirm these figures with the provider before you sign.

Aligned LBB-01 compliance

Aligned Data Centers reports these certifications and attestations for Aligned LBB-01. Ask for current reports during your evaluation.

SOC 2ISO 27001PCI DSSHIPAANIST 800-53

Aligned LBB-01 location

Address
1498 County Road 315, Abernathy, TX 79311

Aligned LBB-01 specifications

Checked against Aligned Data Centers’s website in November 2026. Where the provider’s own sources disagreed, we left the figure out rather than guess. Providers update specs on their own schedule, so we confirm the current numbers with them before you sign.

Power

UPS redundancy2 MW UPS line-ups; N+1 block redundant
Generator redundancy3 MW backup generators
Power distribution415V to racks (A+B); 500 kVA PDUs

Cooling

Cooling redundancyMinimum N+1; closed-loop chilled water

Security

Physical security5-layer security; 24x7x365 onsite security staff; fixed and PTZ cameras
Fire suppressionDual interlocking pre-action zoned fire protection; VESDA early smoke detection

Building

Facility typeHyperscale
Tier designDesigned to Tier III standards

Is Aligned LBB-01 the right fit?

Our read from the published specs, plus what we'd tell you from the inside. We confirm the details with Aligned Data Centers before you commit.

Where it fits

  • Larger deployments, typically hundreds of kW and up, sold as halls, suites or dedicated space
  • Regulated workloads that need SOC 2, ISO 27001, PCI DSS and HIPAA

Insider advice

  • Get usable kW per cabinet in writing. Providers quote breaker size, and a 30A 208V circuit delivers about 5 kW under the 80% rule.
  • Ask about priority fuel delivery contracts, not just tank size. In a regional outage, the sites with priority contracts get fuel first.
  • An SLA credit is a slice of one month's bill. It won't cover your lost revenue, so judge the facility on its incident history, not its credit schedule.
  • Visit day and night. Check lighting, parking and nearby rail, chemical plants, gas lines and flight paths.