Aligned BG-01 Data Center

Zona Franca Metropolitana de Cota, Predio San Rafael, Vereda Vuelta Grande, Cota, Cundinamarca, Colombia

OperationalAligned Data CentersBogotáAligned Data Centers site

  • Wholesale
  • Verified November 2026
  • 3 compliance reports

About Aligned BG-01

Aligned BG-01 is a wholesale data center operated by Aligned Data Centers in Cota. It's one of 4 facilities we track in the Bogotá market, a tier 3 market.

UPS redundancy is 2.4 MW UPS line-ups; tri-bus and generators are 1,650 kW backup generators. Cooling is Minimum N+1; closed-loop chilled water.

Metropolitan Free Trade Zone, 8.8 km from downtown Bogotá. ODATA lists 6,400 m² total and 5,500 m² built (about 68,889 and 59,201 sq ft).

  • Industry leaders, not a call centerOur team brings 20 to 30 years from major data center platforms, the channel and data center brokerage.
  • Pricing in days, not weeksOne request reaches the providers that fit. No chasing reps one by one.
  • We negotiate, you signWe know what buyers in this market pay and use it to get you better terms.

Aligned BG-01 key details

Building size
Not published
Colocation space
Not published
Total power
Not published
Critical IT power
Not published
Availability
Not published
Market
Bogotá
Type
Wholesale
Specs checked
November 2026

Buyer note: Aligned Data Centers does not publish critical IT power, available capacity, power density per rack and carrier count for Aligned BG-01. That is common, and it is exactly what to ask for in writing with your quote. We confirm these figures with the provider before you sign.

Aligned BG-01 compliance

Aligned Data Centers reports these certifications and attestations for Aligned BG-01. Ask for current reports during your evaluation.

SOC 2ISO 27001PCI DSS

Aligned BG-01 location

Address
Zona Franca Metropolitana de Cota, Predio San Rafael, Vereda Vuelta Grande, Cota, Cundinamarca, Colombia

Aligned BG-01 specifications

Checked against Aligned Data Centers’s website in November 2026. Where the provider’s own sources disagreed, we left the figure out rather than guess. Providers update specs on their own schedule, so we confirm the current numbers with them before you sign.

Power

UPS redundancy2.4 MW UPS line-ups; tri-bus
Generator redundancy1,650 kW backup generators

Cooling

Cooling redundancyMinimum N+1; closed-loop chilled water

Security

Fire suppressionDual interlocking pre-action zoned fire protection; VESDA early smoke detection

Building

Facility typeHyperscale
Tier designDesigned to Tier III standard

Is Aligned BG-01 the right fit?

Our read from the published specs, plus what we'd tell you from the inside. We confirm the details with Aligned Data Centers before you commit.

Where it fits

  • Larger deployments, typically hundreds of kW and up, sold as halls, suites or dedicated space
  • Regulated workloads that need SOC 2, ISO 27001 and PCI DSS

Insider advice

  • Get usable kW per cabinet in writing. Providers quote breaker size, and a 30A 208V circuit delivers about 5 kW under the 80% rule.
  • Ask about priority fuel delivery contracts, not just tank size. In a regional outage, the sites with priority contracts get fuel first.
  • An SLA credit is a slice of one month's bill. It won't cover your lost revenue, so judge the facility on its incident history, not its credit schedule.
  • Visit day and night. Check lighting, parking and nearby rail, chemical plants, gas lines and flight paths.

Nearby in Bogotá

Equinix BG1Avenida Carrera 106 No. 15A-25, Bogotá
21,571 sq ft
N+1 UPS
Verified Nov 2026
Equinix BG2Carrera 106 No. 15A-25, Bogotá
43,092 sq ft
N+1 UPS
Verified Nov 2026
12,486 sq ft
N+1 UPS
Verified Nov 2026
All Bogotá Data Centers

Not sure Aligned BG-01 is the one? Get quotes from this facility and comparable options in Bogotá, side by side.

Compare Bogotá quotes

Explore

Work at Aligned Data Centers? Send corrections or new specs.