Netrality 733 West Henry Data Center

733 West Henry Street, Indianapolis, IN 46225

OperationalNetrality Data CentersIndianapolisNetrality Data Centers site

  • Retail colocation
  • Verified November 2026
  • 3 compliance reports

About Netrality 733 West Henry

Netrality 733 West Henry is a colocation data center operated by Netrality Data Centers at 733 West Henry Street in Indianapolis, IN. It's one of 4 facilities we track in the Indianapolis market, a tier 3 market.

The building is 40,000 sq ft. UPS redundancy is N, N+1 and generators are N (4,300 gallons fuel). Cooling is 300-ton chilled water N+1; N+1 CRACs; cold-aisle containment.

36 carriers are available.

  • Industry leaders, not a call centerOur team brings 20 to 30 years from major data center platforms, the channel and data center brokerage.
  • Pricing in days, not weeksOne request reaches the providers that fit. No chasing reps one by one.
  • We negotiate, you signWe know what buyers in this market pay and use it to get you better terms.

Netrality 733 West Henry key details

Building size
40,000 sq ft
Colocation space
Not published
Total power
Not published
Critical IT power
Not published
Availability
Not published
Type
Retail colocation
Specs checked
November 2026

Buyer note: Netrality Data Centers does not publish critical IT power, available capacity and power density per rack for Netrality 733 West Henry. That is common, and it is exactly what to ask for in writing with your quote. We confirm these figures with the provider before you sign.

Netrality 733 West Henry compliance

Netrality Data Centers reports these certifications and attestations for Netrality 733 West Henry. Ask for current reports during your evaluation.

SOC 2PCI DSSHIPAA

Netrality 733 West Henry location

Address
733 West Henry Street, Indianapolis, IN 46225

Netrality 733 West Henry specifications

Checked against Netrality Data Centers’s website in November 2026. Where the provider’s own sources disagreed, we left the figure out rather than guess. Providers update specs on their own schedule, so we confirm the current numbers with them before you sign.

Power

UPS redundancyN, N+1
Generator redundancyN (4,300 gallons fuel)

Cooling

Cooling redundancy300-ton chilled water N+1; N+1 CRACs; cold-aisle containment

Network

Carriers36

Security

Fire suppressionPre-action dry pipe; FM200

Building

Facility typeCarrier hotel
Building size40,000 sq ft
Floor loading150 lbs/sq ft
Flood plainOutside the 500-year flood plain

Is Netrality 733 West Henry the right fit?

Our read from the published specs, plus what we'd tell you from the inside. We confirm the details with Netrality Data Centers before you commit.

Where it fits

  • Cabinets, cages and smaller suites, with the services a retail colocation customer expects
  • Network-heavy workloads with 36 carriers
  • Regulated workloads that need SOC 2, PCI DSS and HIPAA

Insider advice

  • Get usable kW per cabinet in writing. Providers quote breaker size, and a 30A 208V circuit delivers about 5 kW under the 80% rule.
  • Ask what the whips can handle. If they're sized only for today's circuit, more power later means new whips and paying install fees again.
  • Ask about priority fuel delivery contracts, not just tank size. In a regional outage, the sites with priority contracts get fuel first.
  • Visit day and night. Check lighting, parking and nearby rail, chemical plants, gas lines and flight paths.

Nearby in Indianapolis

DataBank IND2 Indianapolis650 West Henry Street, Indianapolis, IN
31,080 sq ft
N+1 UPS
Verified Nov 2026
DataBank Indianapolis731 West Henry Street, Indianapolis, IN
16,950 sq ft
N+1 UPS
Verified Nov 2026
Netrality 701 West Henry701 West Henry Street, Indianapolis, IN
14,500 sq ft
Verified Nov 2026
All Indianapolis Data Centers

Not sure Netrality 733 West Henry is the one? Get quotes from this facility and comparable options in Indianapolis, side by side.

Compare Indianapolis quotes

Explore

Work at Netrality Data Centers? Send corrections or new specs.