About Aligned QR-02
Aligned QR-02 is a wholesale data center operated by Aligned Data Centers in Querétaro. It's one of 11 facilities we track in the Querétaro market, a tier 2 market.
UPS redundancy is 2 MW UPS line-ups; N+1 block redundant and generators are 3 MW backup generators. Cooling is Minimum N+1; closed-loop chilled water.
Former ODATA site.
- Industry leaders, not a call centerOur team brings 20 to 30 years from major data center platforms, the channel and data center brokerage.
- Pricing in days, not weeksOne request reaches the providers that fit. No chasing reps one by one.
- We negotiate, you signWe know what buyers in this market pay and use it to get you better terms.
Aligned QR-02 key details
- Building size
- Not published
- Colocation space
- Not published
- Total power
- Not published
- Critical IT power
- Not published
- Availability
- Not published
- Provider
- Aligned Data Centers
- Market
- Querétaro
- Type
- Wholesale
- Specs checked
- November 2026
Buyer note: Aligned Data Centers does not publish critical IT power, available capacity, power density per rack and carrier count for Aligned QR-02. That is common, and it is exactly what to ask for in writing with your quote. We confirm these figures with the provider before you sign.
Aligned QR-02 compliance
Aligned Data Centers reports these certifications and attestations for Aligned QR-02. Ask for current reports during your evaluation.
Aligned QR-02 location
- Address
- Amexhe Industrial Park, Lot 24, Carretera Federal 45D Querétaro-Celaya km 19.7, Querétaro 76245, Mexico
Aligned QR-02 specifications
Checked against Aligned Data Centers’s website in November 2026. Where the provider’s own sources disagreed, we left the figure out rather than guess. Providers update specs on their own schedule, so we confirm the current numbers with them before you sign.
Power
Cooling
Security
Building
Is Aligned QR-02 the right fit?
Our read from the published specs, plus what we'd tell you from the inside. We confirm the details with Aligned Data Centers before you commit.
Where it fits
- Larger deployments, typically hundreds of kW and up, sold as halls, suites or dedicated space
- Regulated workloads that need SOC 2, ISO 27001, PCI DSS and HIPAA
Insider advice
- Get usable kW per cabinet in writing. Providers quote breaker size, and a 30A 208V circuit delivers about 5 kW under the 80% rule.
- Ask about priority fuel delivery contracts, not just tank size. In a regional outage, the sites with priority contracts get fuel first.
- An SLA credit is a slice of one month's bill. It won't cover your lost revenue, so judge the facility on its incident history, not its credit schedule.
- Visit day and night. Check lighting, parking and nearby rail, chemical plants, gas lines and flight paths.
Nearby in Querétaro
Not sure Aligned QR-02 is the one? Get quotes from this facility and comparable options in Querétaro, side by side.
Compare Querétaro quotesExplore
Work at Aligned Data Centers? Send corrections or new specs.