About Aligned SP-01
Aligned SP-01 is a wholesale data center operated by Aligned Data Centers in Santana de Parnaíba. It's one of 20 facilities we track in the São Paulo market, a tier 2 market.
UPS redundancy is 1 MW UPS line-ups; N+1 block redundant / tri-bus and generators are 1,825 kW backup generators. Cooling is Minimum N+1; closed-loop chilled water.
Former ODATA site. ODATA lists 22,000 m² (about 236,806 sq ft) for this site without saying whether that is building or land area.
- Industry leaders, not a call centerOur team brings 20 to 30 years from major data center platforms, the channel and data center brokerage.
- Pricing in days, not weeksOne request reaches the providers that fit. No chasing reps one by one.
- We negotiate, you signWe know what buyers in this market pay and use it to get you better terms.
Aligned SP-01 key details
- Building size
- Not published
- Colocation space
- Not published
- Total power
- Not published
- Critical IT power
- Not published
- Availability
- Not published
- Provider
- Aligned Data Centers
- Market
- São Paulo
- Type
- Wholesale
- Specs checked
- November 2026
Buyer note: Aligned Data Centers does not publish critical IT power, available capacity, power density per rack and carrier count for Aligned SP-01. That is common, and it is exactly what to ask for in writing with your quote. We confirm these figures with the provider before you sign.
Aligned SP-01 compliance
Aligned Data Centers reports these certifications and attestations for Aligned SP-01. Ask for current reports during your evaluation.
Aligned SP-01 location
- Address
- Estrada dos Romeiros, 943, Votuparim, Santana de Parnaíba, SP 06513-001, Brazil
Aligned SP-01 specifications
Checked against Aligned Data Centers’s website in November 2026. Where the provider’s own sources disagreed, we left the figure out rather than guess. Providers update specs on their own schedule, so we confirm the current numbers with them before you sign.
Power
Cooling
Security
Building
Is Aligned SP-01 the right fit?
Our read from the published specs, plus what we'd tell you from the inside. We confirm the details with Aligned Data Centers before you commit.
Where it fits
- Larger deployments, typically hundreds of kW and up, sold as halls, suites or dedicated space
- Regulated workloads that need ISO 27001 and PCI DSS
Insider advice
- Get usable kW per cabinet in writing. Providers quote breaker size, and a 30A 208V circuit delivers about 5 kW under the 80% rule.
- Ask about priority fuel delivery contracts, not just tank size. In a regional outage, the sites with priority contracts get fuel first.
- An SLA credit is a slice of one month's bill. It won't cover your lost revenue, so judge the facility on its incident history, not its credit schedule.
- Visit day and night. Check lighting, parking and nearby rail, chemical plants, gas lines and flight paths.